Issue 2.0
4-52 Features and Specifications
Centralized Day/Night Mode Change – K-CCIS
FEATURE DESCRIPTION
This feature switches the Day/Night mode of a remote office that is linked to a main
office using K-CCIS, in accordance with the Day/Night mode switching from an
Attendant Position at the main office.
When a UNIVERGE SV9100 system is connected to another UNIVERGE SV9100
system, the main office can control remote offices.
When connected to a NEAX2400, the UNIVERGE SV9100 can be used only as a
remote office.
For more details, refer to the UNIVERGE SV9100 Features and Specifications
Manual.
SYSTEM AVAILABILITY
Terminal Type:
All multiline terminals
Required Components
GCD-CCTA
- OR -
GPZ-IPLE
OPERATING PROCEDURES
To set or cancel Night Transfer system-wide from an Attendant Position:
Main Office:
1. Press Speaker.
2. Dial Access Code 718.
3. Dial the Night service Code:
1 Day 1 mode 5 Day 2 mode
2 Night 1 mode 6 Night 2 mode
3 Midnight 1 mode 7 Midnight 2 mode
4 Rest 1 mode 8 Rest 2 mode
4. Press Speaker or hang up.