Issue 2.0
7-10 H.323 Trunking
2.5.1 CODEC Selection for IP Networking (H.323)
Use the following programs to assign CODEC selections for H.323.
Table 7-8 IP Networking (H.323) CODEC Assignments
Program/
Item No.
Description/
Selection
Assigned Data Comments
84-01-02 H.323 Trunk Basic
Information Setup – Number
of G.711 audio frames
1~4 (SV9100)
Default =3
84-01-03 H.323 Trunk Basic
Information Setup – G.711
VAD mode
0 = Disable
1 = Enable
Default is 0
84-01-04 H.323 Trunk Basic
Information Setup – G.711
Type
0 = A-law
1 = -law
Default is 0
84-01-05 H.323 Trunk Basic
Information Setup – Number
of G.729 audio frames
1~6
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
5 = 50ms
6 = 60ms
Default is 3
84-01-06 H.323 Trunk Basic
Information Setup – G.729
VAD mode
0 = Disable
1 = Enable
Default = 0
84-01-07 H.323 Trunk Basic
Information Setup – G.729
Jitter Buffer (min)
0~300ms
Default is 30
84-01-08 H.323 Trunk Basic
Information Setup – G.729
Jitter Buffer (average)
0~300ms
Default is 60
84-01-09 H.323 Trunk Basic
Information Setup – G.729
Jitter Buffer (max)
0~300ms
Default is 120
84-01-15 H.323 Trunk Basic
Information Setup – Jitter
Buffer Mode
1 = Fixed
3 = Self adjusting
Default is 3
84-01-16 H.323 Trunk Basic
Information Setup – G.711
Jitter Buffer(min)
0~300ms
Default is 30