4-106 Features and Specifications
SERVICE CONDITIONS
General:
In a closed numbering plan, the location of the office can be identified by the
first digit or first two digits of the telephone number.
In an open numbering plan, each office in the K-CCIS network is assigned a
one-, two- or three-digit office code and each station in the office is assigned
telephone numbers from two to eight digits.
In the same office, a station-to-station call is made by dialing the telephone
number of the desired station.
Restrictions:
For a Closed Numbering Plan network, a maximum of 255 systems can be
connected per K-CCIS Network.
When a Closed Numbering plan is used the extensions in the network cannot
have the same prefix number.
For an Open Numbering Plan network, the Automatic Route Selection (ARS)/
Flexible Routing (F-Route) feature must be used to place Station-to-Station
calls over K-CCIS.
When an Open Numbering plan is used, the extensions in the network can
have the same prefix number, however the office location number cannot be
the same.