EasyManua.ls Logo

NEC Univerge SV9100 - Page 497

NEC Univerge SV9100
766 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 2.0
10-10 SV9100 NetLink
After seven days or 28 days the license expires. To renew the license,
a connection to the original Primary site must be re-established.
(Once the connection to the Primary is recovered, if fail-over occurs
again, the license is once again enabled for the specified duration
based on software version above.)
If the original Primary site is in the NetLink network as a temporary
secondary, the license information is available.
If a user wants to enter another additional feature license, it needs to
be entered on the original Primary System.
When fail-over occurs, the Primary System is changed to another
communication server. The IP applications do not know the new
primary IP Address, so the following features are disabled after fail-
over:
SMDR
ACD-MIS
SIP Terminal
Soft Phone
IP K-CCIS
The following Programs are not updated by the Primary System
during fail-over:
Program 10-01, Program 10-02, Program 10-12, Program 10-13,
Program 10-14, Program 10-15, Program 10-16, Program 10-45,
Program 51-01, Program 90-01 or Program 90-09.
Data in SRAM area is not transferred to the Secondary Systems
during fail-over, therefore when fail-over occurs DND and Caller ID
History may be lost.
Mobile Extension is supported only when using the PRI installed in
the Primary System.
When a Secondary System with an ETIA or RTB assigned is added to
a NetLink network, the Primary Systems database does not replicate
the data in Programs 10-55 or 90-61.
When External MOH is assigned, the AUX1 or AUX2 on the front of
the GCD-CP10 can only be utilized at the Primary Site. All Secondary
sites must provide the External MOH input via an ACI Input [PGD(2)-
U10 ADP].
A DT800/DT700 may be registered to either the primary or a
secondary NetLink system. When NetLink is turned on, the system
refers to programs 51-17-01 and 51-17-02 for DT800/DT700 registrar
information.
With both the Primary Site and Secondary Sites can have their own
local MOH source connected to the AUX1 or AUX2 on the front of the
GCD-CP10.

Table of Contents