EasyManua.ls Logo

NEC Univerge SV9100 - Page 568

NEC Univerge SV9100
766 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 2.0
SV9100 Networking Manual 10-81
Description
Use Program 51-17: NetLink DT800/DT700 Server Individual Information Setup
to set the NetLink port information.
Conditions
None
Feature Cross Reference
None
Program 51 : NetLink Service
51-17 :
NetLink DT800/DT700 Server Individual Information Setup
Level:
IN
Input Data
System ID 1~50
Input Data
Item
No.
Item Input Data Default
01
Register Port
Use to set the SIP Register Port of each system.
0 ~ 65535
5080
02
Subscribe Session Port
Use to set the SIP Subscribe Session Port
number of each system when NetLink is used.
0 ~ 65535
5081