Issue 2.0
SV9100 Networking Manual 4-13
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off Hook
Signaling (Automatic
Override)
0 = Off
1 = On
Default is 1
Must be Off for Call Forward – Busy to operate.
15-07-01 Programmable Function
Keys
10 = Call Forward –
Immediate
11 = Call Forward – Busy
12 = Call Forward – No
Answer
13 = Call Forward – Busy
No Answer
Service Codes:
741
742
743
744
14-01-13 Basic Trunk Data Setup –
Trunk-to-Trunk Transfer
Loop Supervision
0 = Disable
1 = Enable
Default is 1
Must be enabled for Trunk-to-Trunk Transfer, Call
Forward – Off-Premise, and tandem trunking.
50-06-01 CCIS Feature Availability –
Link Reconnect
0 = Not Available
1 = Available
Default is 1
To enable or disable Link Reconnect.
50-05-01 CCIS Maximum Call
Forwarding Hop Counter
0~7 Hops
Default is 5
Sets Maximum Hops allowed in a CCIS network.