138 eCobra User's Guide 14402-000 Rev. F
7.6 Installing the Robot Solenoid Kit
Table 7-15. Connecting Spare Air line to User ConnectorDescription
Item Description
1 Joint 1 cover lifted to access spare air line.
2 User air fitting for connecting spare line. Remove factory installed
tubing first.
3 Tubing bundle containing spare air line.
12.
For inverted robots, remove the four screws from the User Connector Panel. See the fol-
lowing figure. Retain the screws for re-assembly
Remove the cover enough so you have access to the tubing.
1
2
Figure 7-14. Connecting Spare Air Line to User Connector, Inverted Robot
Table 7-16. Connecting Spare Air line to User Connector, Inverted Robot Description
Item Description
1 User air fitting for connecting spare line.Remove factory installed
tubing first.
2 User Connector Panel cover (lifted to access spare air line)
13.
Disconnect the tubing from the 6 mm User Air fitting shown in the two preceding fig-
ures. Fold the tubing out of the way and restrain using cable ties.
14.
Locate the spare air line contained in the tubing bundle inside the front end of the
cover. Remove the spare air line from the bundle. The spare air line for Inverted eCo-
bras is in the robot base, rather than under the cover, as in the non-inverted version.
15.
Insert the spare air line into the back of the empty 6 mm User Air fitting.