6-96
• Torque Reference (Setting: 13)
Torque Compensation Bias (Setting: 14)
100%
–10 V
10 V
–100%
0
• Forward Torque Limit (Setting: 10)
Reverse Torque Limit (Setting: 11)
Regenerative Torque Limit (Setting: 12)
100%
–10 V 10 V0
• Forward/Reverse Torque (Speed) Limit (Setting: 15)
100%
10 V
–100%
0
H Multi-function Analog Output Settings (H4)
D Function Selection Parameters
Parameter Display name Setting
range
1,2
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
H4-01 Terminal 21 Sel 1 to 38 --- 2 Basic or Advanced
H4-04 Terminal 23 Sel 1 to 38 --- 3 Basic or Advanced
Note These parameters cannot be changed during operation.
Advanced Operation Chapter