7-37
Setting
value
PageControl modeFunctionSetting
value
Page
Flux
vector
Open loop
Vector
V/f
w/PG
V/f
Function
1D Trim control decrease (ON: d4-02 frequencies are
subtracted from analog frequency references.)
OK OK OK OK 6-84
1E Sample/hold analog frequency reference (ON:
Hold analog value)
OK OK OK OK 6-85
1F Frequency reference terminal 13/14 selection
(ON: select terminal 14)
Valid only when H3-09 is set to â1Fâ.
OK OK OK OK 5-19
20 to
2F
External fault (Desired settings possible)
Input mode: contact a/contact b,
Detection mode: Normal/during operation
Stopping method: Ramp to stop, coast to stop,
fast stop or continue operation.
OK OK OK OK 6-86
30 Reset PID control integration (ON: resets the PID
control integration value)
OK OK OK OK 6-54
31 Hold PID control integration (ON: maintains the
PID control integration value)
OK OK OK OK 6-54
60 DC injection braking command (ON: DC
operation)
OK OK OK OK 6-88
61 External speed search command 1: Maximum
frequency (ON: speed search)
OK --- OK --- 6-88
62 External speed search command 2: Set frequency
(ON: speed search)
OK --- OK --- 6-88
63 Energy save mode (ON: Energy-saving control
set for b8-01, b8-02)
OK OK --- --- 6-13
64 External speed search command OK OK OK OK ---
65 KEB (deceleration operation for momentary
power interruption) command (NC contact)
OK OK OK OK ---
66 KEB (deceleration operation for momentary
power interruption) command (NO contact)
OK OK OK OK ---
71 Speed/torque control change (ON: Torque control) --- --- --- OK 6-89
72 Zero-servo command (ON: Zero-servo lock) --- --- --- OK 6-89
77 Speed control (ASR) proportional gain switch
(ON: C5-03)
--- --- --- OK 6-89