7-39
Setting
value
PageControl modeSetting
value
Page
Flux
vector
Open loop
Vector
V/f
w/PG
V/f
1B During baseblock 2 (OFF: During base block) OK OK OK OK ---
1C Motor 2 selected (ON: motor 2 selected) OK OK OK OK ---
1D Regenerating (ON: Regenerating) --- --- --- OK ---
1E Restart enabled (ON: Restart enabled) OK OK OK OK 6-107
1F Motor overload (OL1) pre-alarm (ON: 90% or
more of the detection level)
OK OK OK OK 6-92
20 Inverter overheat (OH) pre-alarm (ON:
Temperature is above L8-02)
OK OK OK OK 6-92
30 During torque limit (current limit) (ON: During
torque limit)
--- --- OK OK ---
31 During speed limit. (ON: During speed limit) --- --- --- OK ---
33 Zero-servo end (ON: Zero-servo) --- --- --- OK 6-93
37 During run 2 (ON: Frequency output, OFF: Base
block, DC braking, initialization, operation stop.
OK OK OK OK 6-92
H Analog Inputs: H3
Para
Control
 mode
Page
meter
No.
Display
name
range setting ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
H3-01
Signal
selection:
terminal 13
(Voltage)
0:
0 to +10 V
1:
0 to 
±
10 V
0, 1
0 NO B B B B 5-5
T
erm 13
Signal
H3-02
Gain: termi
-
nal 13
Sets the frequency when 10 V
is input, as a percentage of the
maximum frequency
.
H3-03
Bias: termi
-
nal 13
Sets the frequency when 0 V is
input, as a percentage of the