Chapter 4: eMotionBlox-40/60R
Mounting Clearances
NOTE: The mounting of the eMB-40/60R and all terminations at the eMB-
40/60R must be performed in accordance with all local and national standards.
100
200
50
A
B
C
D
B
Figure 4-9. Clearance for the eMB-40/60R. Units are mm.
Surface Air Gap
(A) Sides 50 mm (2 inches)
(B)Back 0 mm
The following two dimensions are from the front of the heat sink.
(C) Front, when wall-mounted 100 mm (4 inches)
(D)Front, when flat-mounted 200 mm (8 inches)
NOTE: These dimensions assume the eMB-40/60R has exposure to outside air,
rather than being in a sealed container. Any sealed container would need to
provide sufficient cooling for the eMB-40/60R’s internal fan to be effective.
05173-060 M Viper 650/850 Robot with eMB-40/60R User's Guide 55