EasyManua.ls Logo

Omron Viper 650 - AC Power Diagrams

Omron Viper 650
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5: System Installation
AC Power Diagrams
10 A
eMB-40/60R
1Ø 200-240 VAC
200–240
VAC 20 A
L
L
N
N
E
E
F1
B
Figure 5-11. Typical AC Power Installation with Single-Phase Supply
Key Meaning Key Meaning
B User-Supplied ACPower Cable L Line
E Earth Ground N Neutral
F1 Fuse, 10A
NOTE:F1 is user-supplied, must be slow-blow.
10 A
LNE
E
L1
L2
L3
F4
F5
A
10 A
200–240 VAC
200–240 VAC
eMB-40/60R
1Ø 200-240 VAC
Figure 5-12. Single-Phase Load across L1 and L2 of a Three-Phase Supply
05173-060 M Viper 650/850 Robot with eMB-40/60R User's Guide 75

Table of Contents

Other manuals for Omron Viper 650

Related product manuals