Chapter 5: System Installation
Table 5-3. Recommended 24 VDC Power Supplies
Vendor Name Model Ratings Mount
OMRON S8FS-G15024C 24 VDC, 6.5 A, 150 W Front Mount
OMRON S8FS-G15024CD 24 VDC, 6.5 A, 150 W DIN-Rail Mount
OMRON S8VK-S24024C 24 VDC, 10 A, 240 W Front Mount
OMRON S8VK-S24024CD 24 VDC, 10 A, 240 W DIN-Rail Mount
Details for 24 VDC Mating Connector
The 24 VDC mating connector and two pins are supplied with each system. They are shipped
in the cable/accessories box.
Table 5-4. 24 VDC Mating Connector Specs
Connector Details
A
B
A: Ground (pin 1, labeled on under side)
B:+24 VDC
Connector receptacle, 2 position, type:
Molex Saber, 18 A, 2-Pin
Molex P/N 44441-2002
Digi-Key P/N WM18463-ND
Pin Details Molex connector crimp terminal,
female, 14-18 AWG
Molex P/N 43375-0001
Digi-Key P/N WM18493-ND
Recommended crimping tool, Molex Hand
Crimper
Molex P/N 63811-0400
Digi-Key P/N WM9907-ND
NOTE: The 24 VDC cable is not supplied with the system, but is available in
the optional Power Cable kit. See List of Cables and Parts on page 58.
Procedure for Creating 24 VDC Cable
1.
Locate the connector and pins from the preceding table.
2.
Use shielded two-conductor cable with 14-16 AWG wire to create the 24 VDC cable.
Select the wire length to safely reach from the user-supplied 24 VDC power supply to
the eMB-40/60R base.
05173-060 M Viper 650/850 Robot with eMB-40/60R User's Guide 71