Monitoring System Components
Monitoring Components and Identifying SNMP Messages 257
Component Name (Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
/SYS/MB/P[0-x]/D[0-11] FRU Host CPU DIMM
FRU
/SYS/MB/P[0-x]/D[0-11]/PRSNT Discrete
sensor
Host CPU DIMM is
present.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/P[0-x]/D[0-11]/SERVICE Indicator Host CPU DIMM
Service Required
LED
Color: Amber
Location: Main board
Off: Normal
On: DIMM was diagnosed as
faulty.
Related Information
■
“System Chassis Components” on page 253
■
“Cooling Unit Components” on page 255
■
“Disk Backplane Components” on page 255
■
“Power Unit Components” on page 257
■
“Processor Components” on page 258
■
“System Board Components” on page 259
■
“System Firmware Components” on page 261
■
“Hard Disk Drive Components” on page 262
Power Unit Components
The following table lists the power unit components.
Component Name (Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
/SYS/PS[0-1] FRU Power supply FRU
/SYS/PS[0-1]/PRSNT Discrete sensor Power Supply is
present.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/PS[0-1]/STATE Discrete sensor Multistate, power
supply sensor type,
per IPMI
Presence detected
Failure detected
Predictive failure
Power supply input lost
Power supply input lost or
out-of-range