Monitoring System Components
Monitoring Components and Identifying SNMP Messages 253
“System Board Components” on page 259
“System Firmware Components” on page 261
“Hard Disk Drive Components” on page 262
System Chassis Components
The following table lists the system chassis components.
Component Name
(Oracle ILOM CLI
Targets)
IPMI
Type
Description Values (if applicable)
/SYS FRU Product information only
/SYS/UUID FRU Unique system ID Derived from host MAC address. Used for PXE
boot and licensing.
/SYS/ACPI State
sensor
Advanced Configuration
and Power Interface
(hidden)
01h-ACPI_ON_WORKING
20h-ACPI_SOFT_OFF
/SYS/VPS Threshold
sensor
Virtual power sensor Watts
/SYS/VPS_CPUS Threshold
sensor
Virtual power sensor
(CPUs)
Watts
/SYS/VPS_MEMORY Threshold
sensor
Virtual power sensor
(Memory)
Watts
/SYS/VPS_FANS Threshold
sensor
Virtual power sensor
(Fans)
Watts
/SYS/INTSW Discrete
sensor
Chassis intrusion switch 01h-Deasserted
02h-Asserted
/SYS/T_AMB Threshold
sensor
Ambient temperature
on system motherboard,
located on the front
indicator module (FIM).
Degrees Celsius
/SYS/TEMP_FAULT Indicator Temperature Fault LED Color: Amber
Location: Front panel
Off: Normal
On: Chassis overtemp fault
/SYS/OK Indicator Power/OK LED Color: Green