Disconnect Cables From the Server
56 Oracle Server X6-2 Service Manual • June 2016
Disconnect Cables From the Server
Caution - The system supplies standby power to the circuit boards when the power cords are
connected even when the system is powered off.
1.
Label all cables connected to the server.
2.
Power down the server.
See “Powering Down the Server” on page 51.
3.
Disconnect the power cords from the rear of the server.
4.
Disconnect all data cables from the rear of the server.
Related Information
■
“Server Back Panel View” on page 16
■
“Powering Down the Server” on page 51
■
“Remove the Server From the Rack” on page 58
■
“Reconnect Data Cables and Power Cords” on page 193
Extend the Server to the Maintenance Position
The following components can be serviced with the server in the maintenance position:
■
Storage drives
■
Fan modules
■
Power supplies
■
DVD drive module
■
PCIe risers
■
PCIe cards and cables
■
SAS cables
■
NVMe cables
■
DIMMs
■
Internal USB flash drives
■
Motherboard battery
■
Processors
■
Disk backplane
■
FIM (front indicator module)
■
Motherboard