Monitoring System Components
258 Oracle Server X6-2 Service Manual • June 2016
Component Name (Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
Power supply input out-of-
range
Configuration error
/SYS/PS[0-1]/P_IN Power sensor Input power draw Watts
/SYS/PS[0-1]/P_OUT Power sensor Output power Watts
/SYS/PS[0-1]/V_IN Voltage sensor Input voltage Volts
/SYS/PS[0-1]/V_12V Voltage sensor 12V output voltage Volts
/SYS/PS[0-1]/V_12V_STBY Voltage sensor 12V standby
output voltage
Volts
/SYS/PS[0-1]/T_OUT Temperature sensor Ambient
temperature
Degrees Celsius
Related Information
■
“System Chassis Components” on page 253
■
“Cooling Unit Components” on page 255
■
“Disk Backplane Components” on page 255
■
“Memory Device Components” on page 256
■
“Processor Components” on page 258
■
“System Board Components” on page 259
■
“System Firmware Components” on page 261
■
“Hard Disk Drive Components” on page 262
Processor Components
The following table lists the processor (CPU) components.
Component Name (Oracle
ILOM CLI Targets)
IPMI Type Description Values (if applicable)
/SYS/MB/P[0-x] FRU Host CPU FRU
/SYS/MB/P[0-x]/PRSNT Discrete
sensor
Host CPU is present. 01h-ENTITY_PRESENT
02h-ENTITY_ABSENT
/SYS/MB/P[0-x]/SERVICE Indicator Host CPU Service
Required LED
Color: Amber
Location: Mainboard
Off: Normal
On: Processor was diagnosed as
faulty.