Monitoring System Components
258 Oracle Server X6-2 Service Manual • June 2016
Component Name (Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
Power supply input out-of-
range
Configuration error
/SYS/PS[0-1]/P_IN Power sensor Input power draw Watts
/SYS/PS[0-1]/P_OUT Power sensor Output power Watts
/SYS/PS[0-1]/V_IN Voltage sensor Input voltage Volts
/SYS/PS[0-1]/V_12V Voltage sensor 12V output voltage Volts
/SYS/PS[0-1]/V_12V_STBY Voltage sensor 12V standby
output voltage
Volts
/SYS/PS[0-1]/T_OUT Temperature sensor Ambient
temperature
Degrees Celsius
Related Information
“System Chassis Components” on page 253
“Cooling Unit Components” on page 255
“Disk Backplane Components” on page 255
“Memory Device Components” on page 256
“Processor Components” on page 258
“System Board Components” on page 259
“System Firmware Components” on page 261
“Hard Disk Drive Components” on page 262
Processor Components
The following table lists the processor (CPU) components.
Component Name (Oracle
ILOM CLI Targets)
IPMI Type Description Values (if applicable)
/SYS/MB/P[0-x] FRU Host CPU FRU
/SYS/MB/P[0-x]/PRSNT Discrete
sensor
Host CPU is present. 01h-ENTITY_PRESENT
02h-ENTITY_ABSENT
/SYS/MB/P[0-x]/SERVICE Indicator Host CPU Service
Required LED
Color: Amber
Location: Mainboard
Off: Normal
On: Processor was diagnosed as
faulty.