Remove a Power Supply
Servicing CRUs That Do Not Require Server Power-Off 81
Related Information
“Troubleshooting Using the Server Front and Rear Panel Status Indicators” on page 28
“Powering Down the Server” on page 51
Power Supply Status Indicators
Each power supply contains two status indicators (LEDs) on the back panel. The following
figure and table provide a description of the power supply status indicators.
FIGURE  14
Power Supply Status Indicators
TABLE 11
Server Power Supply Indicators
Legend Status
Indicator
Name
Icon Color State Meaning
1 AC OK/DC
OK
Green OFF – No AC power is present.
SLOW BLINK – Normal operating. Input power is within
specification. DC output voltage is not enabled.
STEADY ON – Normal operation. Input AC power and
DC output voltage are within specification.
2 Service
Required
Amber OFF – Normal operation; no service required.
STEADY ON – The power supply (PS) has detected a PS
fan failure, PS overtemperature, PS over current, or PS
over/under voltage.
Remove a Power Supply
1.
Identify which power supply requires replacement.
A lit amber Service Required LED on a power supply indicates that a failure was detected.
You can also use the Oracle ILOM show faulty command at the Oracle ILOM command line
prompt (->) to identify a power supply failure.