Returning the Server to Operation 187
Returning the Server to Operation
After replacing components inside of the server, perform the procedures in the following
sections.
Description Links
Learn about filler panels. “Removing and Installing Server Filler Panels
” on page 187
Install the server top cover. “Install the Server Top Cover” on page 188
Remove antistatic measures. “Remove Antistatic Measures” on page 190
Install the server chassis into the rack. “Reinstall the Server Into the Rack” on page 190
Return the server to the normal rack position. “Return the Server to the Normal Rack
Position” on page 191
Reconnecting data cables and power cords. “Reconnect Data Cables and Power Cords” on page 193
Power on the server. “Power On the Server” on page 194
Removing and Installing Server Filler Panels
Each server might be shipped with module-replacement filler panels for storage drives and PCIe
cards. These filler panels are installed at the factory and must remain in the server until you
replace them with a purchased option.
Before you can install an optional server component into the server, you must remove the filler
panel from the location into which you intend to install the component. When you remove a
storage drive or a PCIe card from the server, you must install either a replacement component or
a filler panel.
See the following procedure for instructions for removing and installing the server filler panels:
“Remove and Install Filler Panels” on page 188
Related Information
“Servicing CRUs That Do Not Require Server Power-Off” on page 63
“Servicing CRUs That Require Server Power-Off” on page 85