EasyManua.ls Logo

Oracle X6-2 - Page 273

Oracle X6-2
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Memory Events
Monitoring Components and Identifying SNMP Messages 273
Messages and Descriptions Component Name
Oracle ILOM Event Message: event fault.memory.intel.mrc.unknown-errcode "An unknown
error code from the Memory Reference Code (MRC) has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.sodimm-unsupported "An
unsupported SODIMM has been detected in system."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.sodimm-unsupported "An
unsupported SODIMM has been detected in system."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.4gb-fused "An unsupported 4-gb
memory DIMM has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.4gb-fused "An unsupported 4-gb
memory DIMM has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.8gb-fused "An unsupported 8-gb
memory DIMM has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.8gb-fused "An unsupported 8-gb
memory DIMM has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap: sunHwTrapMemoryFault /SYS/MB/P[0-x]/D[0-11]

Table of Contents

Related product manuals