Parker Hannifin
P series User Guide 220
INSPD signal is output when the current speed is smaller than the set value.
When the motor stops due to servo-off or servo alarm, you can set the output timing
by setting the brake signal output speed(0x2407) and delay time(0x2408). When the
motor‘s rotational speed is under the set speed (0x2407), or the output delay time
(0x2408) lapses after servo off command, the brake signal is output.
See descriptions on 0x2407.
Torque Limit at Homing Using Stopper
Set the torque limit when homing using stopper. Setting the value too high may
damage the machine when hitting the stopper. Please take caution.
Duration Time at Homing Using Stopper
Set the stopper detection time when homing using stopper. Please set the
appropriate value for the machine.
Selects whether to use Modulo function (PD drive is determined depending on
coordinate shaft and Index type).