Parker Hannifin
P series User Guide 228
The temperature is measured with the built in temperature sensor in the drive‘s
power board. When the measured value is 95 or above, the drive overheating alarm
1(AL-22) is set off.
0x260C
Drive Temperature 2
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT
-
-
o
C
RO
No
-
No
The temperature is measured with the built in temperature sensor in the drive‘s
power board. When the measured value is 90 or above, the drive overheating alarm
1(AL-25) is set off.
0x260D
Encoder Temperature
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT
-
-
o
C
RO
No
-
No
Shows the temperature measured by the built in sensor of serial encoders (when encoder format
(0x0201) is 4). When the measured 90 or above, the encoder heat (AL-26)sets off.
0x260E
Motor Rated Speed
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
-
-
rpm
RO
No
-
No
Show the rated speed of the drive motor.
0x260F
Motor Maximum Speed
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
-
-
rpm
RO
No
-
No
Show the drive‘s maximum speed.
0x2610
Drive Rated Current
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
-
-
0.1A
RO
No
-
No
Shows the drive‘s rated current.
0x2611
FPGA Version
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
STRIN
G
-
-
-
RO
No
-
No

Table of Contents