Page #243 background image
Parker Hannifin
P series User Guide 241
Set Value
Descriptions
0
Do not use
1
Deceleration and stop, Switch On Disabled and stop, Ready
status
0x605C
Disable Operation Option Code
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT
0 to 1
1
-
RW
No
At all
times
Yes
Set the option code for disable operation status. (Operation Enable state  Switched
On state).
Set Value
Descriptions
0
Do not use drive function
1
Deceleration and stop, movement with the Switch On
Disable, not ready..
0x605D
Halt Option Code
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT
0 to 4
0
-
RW
No
At all
times
Yes
Halt option code sets the movement method when moving from operation enable state
to switched on state.
Set Value
Descriptions
1
Deceleration and stop, Operation Enabled
2
Deceleration and stop with quick stop deceleration, Operation
Enabled
3
Deceleration and stop with torque limit torque, Operation
Enabled
0x605E
Fault Reaction Option Code
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT
0
0
-
RW
No
At all
times
Yes
Set the action method for fault action to protect the drive‘s system.
Set Value
Descriptions
0
Do not use servo drive functions. Keep the motor at free run.