Section 18: BODY
PA1562
27
Apply Sika 255 onto door frame structure.
Note: Leave some
space at the bottom
(50mm) for water
dripping.
Install and center fiber glass body panel
onto door frame leaving an excess of 3mm
all around the frame.
Line-up body panel with window. There
must be a gap of 4±2mm between window
and body panel.
Apply some masking tape 1mm from
window edge and body panel.
Fill the gap between window and body panel
with Sika 255.
Smooth down the joint with a plastic scraper
then remove masking tape.
Wet Sika joint using water to accelerate the
curing process and put the finishing touch
with your finger.
Discard waste according to applicable
environmental regulations, use dangerous
waste containers.