TABLE A
DISTANCE TRAVELED
1
(miles / km)
6 250 / 10 000
12 500 / 20 000
18 750 / 30 000
25 000 / 40 000
31 250 / 50 000
37 500 / 60 000
43 750 / 70 000
50 000 / 80 000
56 250 / 90 000
62 500 / 100 000
68 750 / 110 000
75 000 / 120 000
81 250 / 130 000
87 500 / 140 000
93 750 / 150 000
100 000 / 160 000
106 250 / 170 000
112 500 / 180 000
118 750 / 190 000
125 000 / 200 000
131 250 / 210 000
137 500 / 220 000
143 750 / 230 000
150 000 / 240 000
185 000 / 300 000
200 000 / 320 000
225 000 / 360 000
250 000 / 400 000
275 000 / 440 000
300 000 / 500 000
500 000 / 800 000
600 000 / 1 000 000
LUBRICATION AND
SERVICING SCHEDULE
Item
Months
proceed to maintenance operation at each
LUBRICANT /PART
2
14 STEERING
Drag link ends, grease one fitting at each end
4 6
K
Relay rod ends, grease one fitting at each end
42 6
K
Steering tie rod ends, grease one fitting at each end
40 6
K
Idler arm, grease fitting
41 6
K
Bell crank, grease fitting
41 6
K
Steering damper cylinder, grease one fitting at rod end
39 6
K
Steering knuckle pins, grease two fittings per knuckle
9 6
K
Power steering reservoir, replace oil and filter cartridges
29 12
B
16 SUSPENSION
Upper A-Arm Ball Joint, grease fitting
6
L
Air bellows, inspect
6
22 HEATING & AIR CONDITIONING
A/C compressor, check oil level, add if necessary
25 6
D
A/C receiver tank, check refrigerant level, add if necessary
37 6
Refrigerant moisture indicator, replace filter dryer unit
according to moisture indicator (as needed)
38 6
A/C and Heating air filters, clean or replace all elements
10 6
P14,P15
Parcel rack fan air filters, clean or replace
- 6
P20
Condenser discharge tube, qty:2, check to see if clogged
9
- 3
Front discharge tube, qty:2, check to see if clogged
10
-3
Evaporator discharge tube, qty:6, check to see if clogged
- 3
Recirculating pump drive motor, inspect brush, replace if
necessary
- 12
9
Discharge tubes are rubber tubes located under vehicle
10
Discharge tubes are rubber tubes located under vehicle

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PREVOST X3-45 Multiplex and is the answer not in the manual?

PREVOST X3-45 Multiplex Specifications

General IconGeneral
Length45 ft
Width102 in
EngineVolvo D13
Horsepower500 hp
GVWR54, 000 lbs
Height146 in
Sleeping CapacityVaries based on floor plan
Water CapacityVaries based on floor plan

Related product manuals