Peeling-off on Demand without Present Sensor
In the peel-off mode with PS800 or PS900 the label removal from the peel position is detected
by an optical sensor.
Using the I/O interface the label removal can be confirmed by the external signal LBLREM. That
way it is possible to operate the printer in peel-off mode without present sensor.
Starting Print and Confirming Label Removal with Two Signals
Requirements:
Operation without present sensor.
External circuit as shown in Figure 51 / Figure 52
Setting Printing > Print on Demand = “On”.
Setting Interfaces > I/O > Automatic LBLREM = “Off”
Operation:
1) Send a print job.
2) Activate START.
The first label will be printed an transported to the peel position.
3) Remove the label.
4) Confirm the label removal with signal LBLREM.