EasyManuals Logo

QuickLabel QL-60 User Manual

QuickLabel QL-60
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Loading Media
QL-30/60 User Guide 39
4 Guide label strip through the label sensor (5) in such a way that it exits the print unit
between the printhead and the print roller.
5 Move guide(s) (6) against the edge(s) of the material by turning the knob (7).
Setting the Label Sensor
The label sensor can be shifted perpendicular to the direction of media flow for adaptation to
the media. The sensor unit (1) of the label sensor is visible from the front through the print unit
and is marked with an indentation in the label sensor retainer. When the printer is switched on,
a yellow LED illuminates the sensor position.
Loosen screw (4).
Position label sensor with tab (5) in such a way that the sensor (1) can detect the label gap
or a reflective or perforation mark.
- or, if the labels deviate from a rectangular shape, -
Align label sensor using the tab (5) with the front edge of the label in the direction of media
flow.
Tighten screw (4).
For use in tear-off mode only:
Turn lever (2) clockwise to lock the printhead.
The label roll is loaded for use in tear-off mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QuickLabel QL-60 and is the answer not in the manual?

QuickLabel QL-60 Specifications

General IconGeneral
BrandQuickLabel
ModelQL-60
CategoryLabel Maker
LanguageEnglish

Related product manuals