I/O Interface
QL-30/60 User Guide 135
Starting Print and Confirming Label Removal with Signal LBLREM
Requirements:
Operation without present sensor.
External circuit as shown in Figure 53 / Figure 54
Setting Printing > Print on Demand = “On”.
Setting Interfaces > I/O > START mode = “Level”.
Setting Interfaces > I/O > Automatic LBLREM = “Off”.
Operation:
1) Hold signal START permanently active.
2) Send a print job.
The first label will be printed and transported to the peel position.
3) Remove the label.
4) Confirm the label removal with signal LBLREM.