Section 6 ROM
Rev. 7.00 Mar 10, 2005 page 183 of 652
REJ09B0042-0700
Table 6.17 AC Characteristics in Auto-Program Mode
Conditions: V
CC
= 3.3 V ±0.3 V, V
SS
= 0 V, T
a
= 25°C ±5°C
Item Symbol Min Max Unit Notes
Command write cycle t
nxtc
20 — µs Figure 6.17
CE
hold time t
ceh
0—ns
CE
setup time t
ces
0—ns
Data hold time t
dh
50 — ns
Data setup time t
ds
50 — ns
Write pulse width t
wep
70 — ns
Status polling start time t
wsts
1—ms
Status polling access time t
spa
— 150 ns
Address setup time t
as
0—ns
Address hold time t
ah
60 — ns
Memory write time t
write
1 3000 ms
WE
rise time t
r
—30ns
WE
fall time t
f
—30ns
CE
A15−A0
OE
WE
I/O7
I/O6
I/O5−I/O0
t
wep
t
ds
t
dh
t
f
t
r
t
as
t
ah
t
wsts
t
write
t
spa
t
ces
t
ceh
t
nxtc
t
nxtc
Address
stable
H'40 H'00
Data transfer
1 to 128 bytes
Write operation end decision signal
Write normal end decision signal
Figure 6.17 Auto-Program Mode Timing Waveforms

Table of Contents

Other manuals for Renesas H8 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas H8 Series and is the answer not in the manual?

Renesas H8 Series Specifications

General IconGeneral
BrandRenesas
ModelH8 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals