Section 16 Electrical Characteristics
Rev. 7.00 Mar 10, 2005 page 470 of 652
REJ09B0042-0700
16.4 H8/38024 Group F-ZTAT Version and H8/38024R Group F-ZTAT
Version Electrical Characteristics
16.4.1 Power Supply Voltage and Operating Range
The power supply voltage and operating range are indicated by the shaded region in the figures.
Power Supply Voltage and Oscillator Frequency Range
38.4
2.7 3.6
V
CC
(V)
f
W
(kHz)
• All operating
32.768
2.0
10.0
2.7 3.6
V
CC
(V)
fosc (MHz)
• Active (high-speed) mode
• Sleep (high-speed) mode
Note: The fosc values are those when an oscillator
is used; when an external clock is used the
minimum value of fosc is 1 MHz.