EasyManua.ls Logo

Renesas H8 Series

Renesas H8 Series
697 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6 ROM
Rev. 7.00 Mar 10, 2005 page 186 of 652
REJ09B0042-0700
Table 6.19 AC Characteristics in Status Read Mode
Conditions: V
CC
= 3.3 V ±0.3 V, V
SS
= 0 V, T
a
= 25°C ±5°C
Item Symbol Min Max Unit Notes
Read time after command write t
nxtc
20 — µs Figure 6.19
CE
hold time t
ceh
0—ns
CE
setup time t
ces
0—ns
Data hold time t
dh
50 — ns
Data setup time t
ds
50 — ns
Write pulse width t
wep
70 — ns
OE
output delay time t
oe
— 150 ns
Disable delay time t
df
— 100 ns
CE
output delay time t
ce
— 150 ns
WE
rise time t
r
—30ns
WE
fall time t
f
—30ns
CE
A15−A0
OE
WE
I/O7−/O0
t
wep
t
f
t
r
t
oe
t
df
t
ds
t
ds
t
dh
t
dh
t
ces
t
ceh
t
ce
t
ceh
t
nxtc
t
nxtc
t
nxtc
t
ces
H'71
t
wep
t
f
t
r
H'71
Note: I/O2 and I/O3 are undefined.
Figure 6.19 Status Read Mode Timing Waveforms

Table of Contents

Other manuals for Renesas H8 Series

Related product manuals