EasyManuals Logo

Renesas H8 Series Hardware Manual

Renesas H8 Series
697 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Rev. 7.00 Mar 10, 2005 page xxviii of xlii
Item Page Revision (See Manual for Details)
B.2 Functions
AMR—A/D Mode
Register
587 Clock Select and notes amended
Clock Select
62/φ
Bit 7
0
Conversion PeriodCKS
31/φ1
62 µs
φ = 1 MHz
31 µs
12.4 µs
φ = 5 MHz

*
1
6.2 µs
φ = 10 MHz
*
2

*
1
Conversion Time
Notes: 1. Except for the H8/38124 Group, operation cannot be
guaranteed if the conversion time is less than 12.4 µs.
Make sure to select a setting that gives a conversion time of
12.4 µs or more in such cases. For the H8/38124 Group select
a setting that gives a conversion time of 6.2 µs or more.
2. H8/38124 Group only.
C.8 Block Diagrams
of Port 9
Figure C.8(c) Port 9
Block Diagram (Pin
P9
3
, H8/38124 Group
only)
633 Newly added
C.10 Block Diagrams
of Port B
Figure C.10(a) Port
B Block Diagram
635 Title amended
Figure C.10(b) Port
B Block Diagram (Pin
PB
0
, H8/38124 Group
only)
636 Newly added
Figure C.10(c) Port B
Block Diagram (Pin
PB
1
, H8/38124 Group
only)
637 Newly added

Table of Contents

Other manuals for Renesas H8 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas H8 Series and is the answer not in the manual?

Renesas H8 Series Specifications

General IconGeneral
BrandRenesas
ModelH8 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals