Rev. 7.00 Mar 10, 2005 page xxviii of xlii
Item Page Revision (See Manual for Details)
B.2 Functions
AMR—A/D Mode
Register
587 Clock Select and notes amended
Clock Select
62/φ
Bit 7
0
Conversion PeriodCKS
31/φ1
62 µs
φ = 1 MHz
31 µs
12.4 µs
φ = 5 MHz

*
1
6.2 µs
φ = 10 MHz
*
2

*
1
Conversion Time
Notes: 1. Except for the H8/38124 Group, operation cannot be
guaranteed if the conversion time is less than 12.4 µs.
Make sure to select a setting that gives a conversion time of
12.4 µs or more in such cases. For the H8/38124 Group select
a setting that gives a conversion time of 6.2 µs or more.
2. H8/38124 Group only.
C.8 Block Diagrams
of Port 9
Figure C.8(c) Port 9
Block Diagram (Pin
P9
3
, H8/38124 Group
only)
633 Newly added
C.10 Block Diagrams
of Port B
Figure C.10(a) Port
B Block Diagram
635 Title amended
Figure C.10(b) Port
B Block Diagram (Pin
PB
0
, H8/38124 Group
only)
636 Newly added
Figure C.10(c) Port B
Block Diagram (Pin
PB
1
, H8/38124 Group
only)
637 Newly added