GX-6000 Operator’s Manual Other Accessories • 16
External Dilution Fitting
A 1:1 external dilution fitting is available for the GX-6000. It is designed to
mate with the inlet fitting and accept the sample hose and probe. The fitting is
made with brass and nickel plated brass and is appropriate for use with the
four standard gases. The fitting is normally used when it is necessary to
introduce air into a sample that has no oxygen or a very low level of oxygen,
such as a nitrogen purged sample. It can also be used when one of the target
gas levels in the sample area will likely be present in a concentration above
the detection range for that gas. Since the fitting partially consists of unplated
brass, it is not appropriate for detection of elevated levels of H
2
S or of gases
that are easily absorbed such as Cl
2
or SO
2
.
Figure 4: 1:1 Dilution Fitting
DIN Rail Mounting Assembly
Two different DIN rail mounting assemblies are available for the GX-6000’s
charger. Each assembly has two end clamps but one assembly is long enough
to accommodate 1 charger and the other assembly is long enough to
accommodate 4 chargers.
Figure 5: DIN Rail Dimensions
1 . Use #10 screws to mount the DIN rail to the wall.
4" for 1-Charger Model
14" for 4-Charger Model
Use #10 Screws to Mount
1.38"