Function Variants Weighbridge ZEUS
Single Weighing
Follow these steps:
Insert new weigh slip into printer.
Identify vehicle.
Preset empty weight.
Release weighing operation.
Print weigh data.
If vehicle is unloaded, perform single weighing on incoming vehicle; if not, on outgoing
vehicle.
Home position, ZEUS display field
G 12.50 t
Follow these steps:
Press key F3 (perform single weighing)
f vehicle number (truck or wagon number).
Identify Vehicle
System prompts for input o
Example:
VehNo: 345 XYZ
(Max. 10 digits)
Acknowledge.
Identify Load (material number and type)
System prompts for material selection. Material number can be used to form
tive total (weighing results of stored materials, numbers 10 to 25, are
ted) and printed on weigh slip.
cumula
summa
Mat.:0
(Numbers 0...25 or -1)
mes are assigned to numbers 1 to 25. For details, please see Further
.
e:
Material na
functions
Exampl
Mat.:3
Materials not stored can be designated direct by input of material number -1.
Mat.:-1
Acknowledge suggestion (0 = no material type indicated) or overwrite.
After input of -1, system prompts for input of material name to be printed on
Text: ________
weigh slip.
(Max. 12 digits)
BV-H2313 GB 0630 DISOMAT
®
Opus – Operating Manual
- 124 - © Schenck Process GmbH, Darmstadt

Table of Contents