Sequentix Music Systems
Cirklon Sequencer User Manual
6-7
48ppqn DIN sync - DIN SYNC normally outputs 24 pulse per quarter note, as used
by most Roland equipment. This option doubles the output clock rate to 48ppqn, suitable for
use with equipment made by Korg and others.
number of TRACKS - this option allows you to vary the maximum number of tracks
available. The value can be 16, 32, 48 or 64. When more than 16 tracks are enabled, the track
keys and encoders will switch between banks of 16 tracks as described in section 2.
Note that lowering this value may affect playback of existing songs which use track numbers
above the new limit.
edit track bank follow - when changing the bank of tracks assigned to the track keys and
encoders, the current edit track will be changed. This can prevent confusion when the edit
track is not visible in the current bank.
SHIFT+[trk] mutes active - holding SHIFT and pressing a track key to arm” a track for
unmuting will also apply to active tracks, muting them at the next global bar loop.