Cirklon Sequencer User Manual
The frame start pos for the second board should therefore be 20.
You would set the value to 20 on the board config page, then use the [send to board] option
to update its configuration.
You may choose to use fewer than the maximum 16 of the trigger outputs using the trig count
option.
You can choose whether to output DIN SYNC from the second module by setting the DIN
aux enable option.
This option must be enabled to use the DIN output either for DIN SYNC, or for extra note-
triggered outputs.
The output numbers for the 3 pins of the DIN output will always follow the last normal
trigger output set with the trig count value.
For example, if trig count is set to 8 with DIN aux enable on, the three DIN pins will be
triggers 9, 10 and 11 for that module ā the 3.5mm trigger and accent outputs 9 to 16 will be
inactive.
Assuming both modules will use all 16 outputs and send DIN SYNC, the total frame size
should be set to 38.
The first module will respond to trigger numbers 1 to 19, the second to trigger numbers 20 to
38.
The additional trigger settings will become accessible on the trigger map page as soon as the
frame size is increased.
Once configured with the correct frame start pos, each board will respond to pulse length
adjustments according to its own trigger number range.
The pulse length values are edited with all modules connected.