8 Commissioning
8.1 Safety
WARNING
H
azard due to lack of effectiveness of the protective device
b
Before commissioning the machine, make sure that the machine is first checked
and released by qualified safety personnel.
b
Only operate the machine with a perfectly functioning protective device.
DANGER
D
angerous state of the machine
During commissioning, the machine or the protective device may not yet behave as you
have planned.
b
Make sure that there is no-one in the hazardous area during commissioning.
DANGER
H
azard due to lack of effectiveness of the protective device
When changes are made to the machine, the effectiveness of the protective device may
be affected unintentionally.
b
After every change to the machine and changes to the integration or operational
and secondary conditions of the safety laser scanner, check the protective device
for effectiveness and recommission as specified in this chapter.
Before initial commissioning, project planning, mounting, electrical installation and con‐
f
iguration must be completed in accordance with the following chapters:
"Project planning", page 25
"Mounting", page 63
"Electrical installation", page 71
"Configuration", page 74
8.2 Alignment
The following options are available to you for precisely aligning the safety laser scanner
usin
g mounting kit 2a or 2b:
COMMISSIONING 8
8021913/15ZW/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro
117
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 - EFI-pro and is the answer not in the manual?

SICK microScan3 - EFI-pro Specifications

General IconGeneral
Scanning angle275°
Number of fieldsUp to 128
Number of monitoring casesUp to 128
Enclosure ratingIP65, IP67
Number of protective fieldsUp to 128
Field setsUp to 128
Protective field range5.5 m
Resolution30 mm / 40 mm / 50 mm / 70 mm / 150 mm
InterfaceEthernet/IP, PROFINET
Ambient operating temperature0 °C ... +50 °C
Scanning range5.5 m (protective)
Safety integrity levelSIL3 (IEC 61508)
Performance levelPL e (ISO 13849)
TypeType 3
Detection capability30 mm
Operating voltage19.2 V DC to 30 V DC
Ambient temperature0°C to +50°C
Storage temperature-25 °C ... +70 °C
Housing materialAluminum
ConnectionM12 connector
Safety standardsIEC 61496-1, IEC 61508, ISO 13849