EasyManuals Logo

SICK microScan3 - EFI-pro User Manual

SICK microScan3 - EFI-pro
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Reading and transmitting values
If t
he values in the project and the values in the device differ, you can read the values
out from the device and adopt them in the project. Alternatively, you can transmit val‐
ues from the project to the device.
b
Click on Read from the device.
The values are read from the device and adopted in the project.
b
Click on Transmit to device.
The values from the project are transmitted to the device.
If the device has already been configured, the entire configuration will be transmit‐
ted from the project to the device with the IP settings.
7.5 Reading configuration
At the left, you see the values configured in the project for the device. If the device is
connec
ted, you see the values saved in the device at the right.
If the values in the project and the values in the device differ, you can read the values
out from the device and adopt them in the project.
b
Click on Read from the device.
The values are read from the device and adopted in the project.
Configuration
N
ame
If a number of safety laser scanners are used in an application or in a project, a
unique device name helps to tell the individual devices apart.
Chec
ksums
A checksum is used as a unique identification for a configuration. Using the check‐
sum, it is pos
sible to work out whether a setup was changed or whether two
devices have the same configuration.
The checksum of the configuration in the project may not match the checksum in
the device, for example if a field geometry has been modified, but not yet transmit‐
ted to the device.
CONFIGURATION 7
8021913/15ZW/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro
83
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 - EFI-pro and is the answer not in the manual?

SICK microScan3 - EFI-pro Specifications

General IconGeneral
Scanning angle275°
Number of fieldsUp to 128
Number of monitoring casesUp to 128
Enclosure ratingIP65, IP67
Number of protective fieldsUp to 128
Field setsUp to 128
Protective field range5.5 m
Resolution30 mm / 40 mm / 50 mm / 70 mm / 150 mm
InterfaceEthernet/IP, PROFINET
Ambient operating temperature0 °C ... +50 °C
Scanning range5.5 m (protective)
Safety integrity levelSIL3 (IEC 61508)
Performance levelPL e (ISO 13849)
TypeType 3
Detection capability30 mm
Operating voltage19.2 V DC to 30 V DC
Ambient temperature0°C to +50°C
Storage temperature-25 °C ... +70 °C
Housing materialAluminum
ConnectionM12 connector
Safety standardsIEC 61496-1, IEC 61508, ISO 13849