Display Reference Contour Field
Y
ou determine whether the reference contour field is displayed.
Drawing area
You can use a Cartesian or a polar coordinates system and select the colors for the grid
and the drawing area.
b
Choose the option Cartesian.
The coordinates system is shown as a Cartesian coordinates system.
b
Choose the option Polar.
The coordinates system is shown as a polar coordinates system.
b
Select Color of grid.
The field editor’s grid is displayed in the chosen color.
b
Select Color of drawing area.
The field editor’s drawing area is displayed in the chosen color.
7.10.6 Editing fields using coordinates
You can use coordinates to edit fields. Depending on the form on which a field is based,
t
he appropriate input fields are displayed. The example shows a dialog box for a rectan‐
gle.
CONFIGURATION 7
8021913/15ZW/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro
99
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 - EFI-pro and is the answer not in the manual?

SICK microScan3 - EFI-pro Specifications

General IconGeneral
Scanning angle275°
Number of fieldsUp to 128
Number of monitoring casesUp to 128
Enclosure ratingIP65, IP67
Number of protective fieldsUp to 128
Field setsUp to 128
Protective field range5.5 m
Resolution30 mm / 40 mm / 50 mm / 70 mm / 150 mm
InterfaceEthernet/IP, PROFINET
Ambient operating temperature0 °C ... +50 °C
Scanning range5.5 m (protective)
Safety integrity levelSIL3 (IEC 61508)
Performance levelPL e (ISO 13849)
TypeType 3
Detection capability30 mm
Operating voltage19.2 V DC to 30 V DC
Ambient temperature0°C to +50°C
Storage temperature-25 °C ... +70 °C
Housing materialAluminum
ConnectionM12 connector
Safety standardsIEC 61496-1, IEC 61508, ISO 13849