microScan3 Core – EFI-pro microScan3 Pro – EFI-pro
Measurement error with mea‐
sur
ement data output
Typ. ± 25 mm
1)
In the event of heavy contamination, the safety laser scanner displays a contamination fault and switches
all s
afety outputs to the OFF state.
2)
In close proximity (50 mm wide area in front of the optics cover), the detection capability of the safety
la
ser scanner may be restricted. If required, this area must be secured using an undercut or frame, for
example.
13.4 Response times
The protective device’s response time is the maximum time between the occurrence of
t
he event leading to the sensor’s response and supply of the switch-off signal to the
protective device’s interface (for example OFF state of the OSSD pair).
DANGER
H
azard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
In addition to the protective device’s response time, further signal transmission and
processing also influence the time up until the end of the dangerous state. These
include the network cycle time, a control’s processing time and the response times of
downstream contactors, for example.
b
Take the time for further signal transmission and processing into account.
Response time
T
he safety laser scanner’s response time depends on the following parameters:
•
Scan cycle time
•
Set interference protection
•
Set multiple sampling
You can calculate the response time using the following formula:
t
R
= (t
S
+ t
I
) × n + t
O
The following rules apply:
•
t
R
= response time
•
t
S
= scan cycle time
°
Setting “30 ms”: t
S
= 30 ms
°
Setting “40 ms”: t
S
= 40 ms
°
Setting “50 ms”: t
S
= 50 ms
•
t
I
= time for interference protection
°
Mode 1 (default): t
I
= 0 ms
°
Mode 2: t
I
= 1 ms
°
Mode 3: t
I
= 2 ms
°
Mode 4: t
I
= 3 ms
•
n = set multiple sampling
Preset to n = 2.
Multiple sampling can be changed for the safety laser scanner or for each individ‐
ual f
ield (2 ≤ n ≤ 16).
•
t
O
= t
ime for processing and output
Dependent on output used:
°
E
FI-pro: t
O
= 35 ms
TECHNICAL DATA 13
8021913/15ZW/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro
157