Mounting with deflector plates
Figure 20: Mounting with deflector plates (example)
b Attach the deflector plates 1 so that it is not possible to step into unsecured
areas.
b
Attach the deflector plates so that they lie outside the scan plane.
Mounting in an undercut
Figure 21: Mounting in an undercut (example)
b
Mount t
he safety laser scanner in an undercut so that no-one can enter the unse‐
cured areas.
b Make the undercut at least deep enough 1, that it covers the unsecured areas
completely and no one can enter the unsecured areas.
b Prevent crawling beneath the undercut. Design the undercut to be so low 2, that
no one can crawl into it.
PROJECT PLANNING 4