Contents
1 About this document........................................................................ 8
1.1 Function of this document....................................................................... 8
1.2 Scope......................................................................................................... 8
1.3 Target groups of these operating instructions........................................ 8
1.4 Further information................................................................................... 8
1.5 Symbols and document conventions...................................................... 9
2 Safety information............................................................................ 10
2.1 General safety notes................................................................................ 10
2.2 Intended use............................................................................................. 11
2.3 Inappropriate use..................................................................................... 11
2.4 Requirements for personnel qualifications............................................. 11
3 Product description........................................................................... 13
3.1 Setup and function................................................................................... 13
3.2 Product characteristics............................................................................ 15
3.2.1 Device overview....................................................................... 15
3.2.2 Variants.................................................................................... 16
3.2.3 Status indicators...................................................................... 16
3.2.4 Connections............................................................................. 17
3.2.5 System plug.............................................................................. 17
3.2.6 Field types................................................................................ 17
3.2.7 Field set.................................................................................... 20
3.2.8 Monitoring case....................................................................... 21
3.2.9 Simultaneous monitoring........................................................ 22
3.3 Example applications............................................................................... 22
4 Project planning................................................................................ 25
4.1 Manufacturer of the machine.................................................................. 25
4.2 Operator of the machine.......................................................................... 25
4.3 Assembly................................................................................................... 25
4.3.1 Protection from influences...................................................... 27
4.3.2 Preventing unprotected areas................................................. 28
4.3.3 Response time of the safety laser scanner........................... 30
4.3.4 Reference contour monitoring................................................ 30
4.3.5 Monitoring case switching time.............................................. 32
4.3.6 Hazardous area protection...................................................... 34
4.3.7 Hazardous point protection..................................................... 41
4.3.8 Access protection.................................................................... 44
4.3.9 Mobile hazardous area protection.......................................... 46
4.4 Integrating the equipment into the electrical control............................. 52
4.4.1 Voltage supply.......................................................................... 53
4.4.2 USB connection....................................................................... 54
4.4.3 Control inputs........................................................................... 54
CONTENTS
8021913/15ZW/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro
3
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 - EFI-pro and is the answer not in the manual?

SICK microScan3 - EFI-pro Specifications

General IconGeneral
Scanning angle275°
Number of fieldsUp to 128
Number of monitoring casesUp to 128
Enclosure ratingIP65, IP67
Number of protective fieldsUp to 128
Field setsUp to 128
Protective field range5.5 m
Resolution30 mm / 40 mm / 50 mm / 70 mm / 150 mm
InterfaceEthernet/IP, PROFINET
Ambient operating temperature0 °C ... +50 °C
Scanning range5.5 m (protective)
Safety integrity levelSIL3 (IEC 61508)
Performance levelPL e (ISO 13849)
TypeType 3
Detection capability30 mm
Operating voltage19.2 V DC to 30 V DC
Ambient temperature0°C to +50°C
Storage temperature-25 °C ... +70 °C
Housing materialAluminum
ConnectionM12 connector
Safety standardsIEC 61496-1, IEC 61508, ISO 13849