7.4 Addressing
Overview
Figure 58: Addressing
1
Values in the project
2
Values in the device
3
Buttons to read or transmit values
NOTE
If a de
vice has already been configured, the entire configuration will be transmitted
from the project to the device when the IP settings are changed. The configuration of
the control may also be invalid.
b
Before changing the IP settings: read the configuration from the safety laser scan‐
ner with Safety Designer and save if necessary.
Addressing
In or
der to enable communication between the device and the SICK safety controller or
a PC, please enter the IP settings here. The IP address for the device must be unique in
the network and it must be in the same subnet as the IP address for the SICK safety
controller.
b
Enter the IP address, subnet and, if necessary, router IP address.
7 C
ONFIGURATION
82
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro 8021913/15ZW/2019-11-14 | SICK
Subject to change without notice