Loading...
Figure 41: How the restart interlock works (3): person in hazardous area, no detection in protec‐
t
ive field, safety output still in OFF state
Figure 42: How the restart interlock works (4): the reset pushbutton must be pressed before
restarting the machine.
DANGER
H
azard due to unexpected starting of the machine
b
Affix the control switch for resetting the restart interlock outside the hazardous
area.
b
Make sure that the control switch cannot be activated by a person who is in the
hazardous area.
b
Also make sure that the person activating the control switch has a complete view
of the hazardous area.