c
ompliance with standards
°
correct use of the protective device
°
suitable configuration and safety function
°
correct alignment
•
The documentation matches the state of the machine, incl. the protective device
•
The verified configuration report corresponds to the desired project planning (see
"Verifying configuration", page 112)
The thorough checks must be carried out by qualified safety personnel or specially qual‐
ified and authorized personnel and must be documented in a traceable manner.
In many cases, other data must be documented, see "Reports", page 113.
Additional thorough checks for EFI-pro
•
Chec
k EFI-pro connections and ensure they function as intended.
•
Check all settings related to EFI-pro in the configuration.
•
Before entering the configuration signature into the configuration of the control:
check the configuration of the safety laser scanner.
Recommended thorough checks
In many cases, it makes sense to carry out the following thorough checks during com‐
missioning and in certain situations:
•
Thorough check of the relevant points on the checklist, see "Checklist for initial
commissioning and commissioning", page 182
•
"Thorough visual check of the machine and the protective device", page 61
•
"Thorough check of the principal function of the protective device", page 60
•
"Thorough check of the area to be protected", page 60
•
"Test of the contour detection field", page 61
•
Make sure that the operating personnel has been instructed in the protective
device’s function before starting work on the machine. The instruction is the
responsibility of the machine operator and must be carried out by qualified per‐
sonnel.
8 C
OMMISSIONING
120
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro 8021913/15ZW/2019-11-14 | SICK
Subject to change without notice