Parameter reference
8.7 Maintenance and Diagnostics (3.)
HydroRanger 200 HMI
252 Operating Instructions, 06/2018, A5E36281317-AC
8.6.14.6
Totalizer multiplier (2.14.5.)
Use this feature if the LCD Total increments by too large (or too small) an amount.
Index
Single-point model
Dual-point model
Global
Transducer
Options
0.001
0.01
0.1
*1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
Related
Running totalizers high (2.14.2.) (Page 250)
Running totalizers low (2.14.3.) (Page 251)
Enter the factor (powers of 10 only) by which actual volume is divided, prior to display on the
LCD. Use a value such that the eight-digit totalizer doesn’t roll over between readings.
Example:
For an LCD Total display in 1000s of volume units, choose option 1,000.
8.7
Maintenance and Diagnostics (3.)
8.7.1
Identification (3.1.)
8.7.1.1
Tag (3.1.1.)
Sets the text to label the device. Limited to 32 alphanumeric characters. Appears at the top
left corner of the display in Measurement mode. For more information, see The local display
(Page 51).
8.7.1.2
Descriptor (3.1.2.)
Sets the text that can be used in any way. Limited to 32 ASCII characters. No specific
recommended use.
8.7.1.3
Message (3.1.3.)
Sets the text that can be used in any way. Limited to 32 ASCII characters. No specific
recommended use.