Diagnostics
5.2 Diagnostics via STARTER
Function Manual
100 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Starting/stopping the measuring function
CAUTION
With the corresponding measuring function parameter settings (e.g. offset), the motor can
"drift" and travel to its end stop.
The movement of the drive is not monitored while the measuring function is active.
To start the measuring function:
1. Ensure that the prerequisites for starting the measuring function are fulfilled.
– Activate the control panel.
Drive_1 → Commissioning → Control panel
– Switch on the drive.
Control board → Issue enable signals → Switch on
2. Select the drive (as control panel).
3. Set the measuring function.
e.g. current controller setpoint change
4. Load the settings to the target system ("Download parameterization" button).
5. Start the ramp-function generator ("Start measuring function" button)
To stop the measuring function:
● "Stop measuring function" button
Parameterization
The "Measurement function" parameter screen is selected via the following icon in the
toolbar of the STARTER commissioning tool.
Figure 5-8 STARTER icon for "Measuring function"