EasyManua.ls Logo

Siemens SINAMICS S110 - BICO Technology

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic information about the drive system
10.4 BICO technology: Interconnecting signals
Function Manual
678 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
10.4.6 BICO technology:
Copying drives
When a drive is copied, the interconnection is copied with it.
Binector-connector converters and connector-binector converters
Binector-connector converter
Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer
word.
p2080[0...15] BI: PROFIdrive PZD send bit-serial
Connector-binector converter
A 32-bit integer double word or a 16-bit integer word is converted to individual digital
signals.
p2099[0...1] CI: PROFIdrive PZD selection receive bit-serial
Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
p2900[0...n] CO: Fixed value_%_1
p2901[0...n] CO: Fixed value_%_2
p2930[0...n] CO: Fixed value_M_1
Example:
These parameters can be used to interconnect the scaling factor for the main setpoint or to
interconnect an additional torque.

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals