EasyManua.ls Logo

Siemens SINAMICS S110 - SIMATIC HMI Addressing

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication
9.3 Communication via PROFIBUS DP
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
595
9.3.2.4 SIMATIC HMI addressing
You can use a SIMATIC HMI as a PROFIBUS master (master class 2) to access SINAMICS
directly. With respect to SIMATIC HMI, SINAMICS behaves like a SIMATIC S7. For
accessing drive parameters, the following simple rule applies:
Parameter number = data block number
Parameter sub-index = bit 0 ... 9 of data block offset
Drive object number = bit 10 ... 15 of data block offset
Pro Tool and WinCC flexible
The SIMATIC HMI can be configured flexibly with "Pro Tool" or "WinCC flexible".
The following specific settings for drives must be observed when configuration is carried out
with Pro Tool or WinCC flexible.
Controllers: Protocol always "SIMATIC S7 - 300/400"
Table 9- 35 Other parameters
Field Value
Network parameter profile DP
Network parameter baud rate Any
Communication partner address PROFIBUS address of the drive unit
Communication partner
slot/subrack
don’t care, 0
Table 9- 36 Tags: "General" tab
Field Value
Name Any
Control Any
Type Depending on the addressed parameter value,
e.g.:
INT: for integer 16
DINT: for integer 32
WORD: for unsigned 16
REAL: for float
Area DB
DB
(data block number)
Parameter number
1 ... 65535
DBB, DBW, DBD
(data block offset)
Drive object No. and sub-index
bit 15 ... 10: Drive object No. 0 ... 63
bit 9 ... 0: Sub-index 0 ... 1023
or expressed differently
DBW = 1024 * drive object No. + sub-index
Length Not activated
Acquisition cycle Any
No. of elements 1
Decimal places Any

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals