Communication
9.2 Communication according to PROFIdrive
Function Manual
532 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
9.2.3.2 Description of control words and setpoints
Note
This chapter describes the assignment and meaning of the process data in SINAMICS
interface mode (p2038 = 0).
The reference parameter is also specified for the relevant process data. The process data
are generally normalized in accordance with parameters p2000 to r2004.
The following scalings apply:
A temperature of 100°C = 100% and 0°C = 0%
An electrical angle of 90° = 100 % and 0° = 0%.
Overview of control words and setpoints
Table 9- 3 Overview of control words and setpoints, profile-specific
Abbreviation
Signal
Name Signal
number
Data type
1)
Interconnection
parameters
STW1 Control word 1 1 U16 (bit-serial)
2)
STW2 Control word 2 3 U16 (bit-serial)
2)
NSOLL_A Speed setpoint A (16-bit) 5 I16 p1155
p1070(ext.setp.)
NSOLL_B Speed setpoint B (32-bit) 7 I32 p1155
p1070 (ext.setp.)
G1_STW Encoder 1 control word 9 U16 p0480[0]
G2_STW Encoder 2 control word 13 U16 p0480[1]
A_DIGITAL Digital output (16 bits) 22 U16 (bit-serial)
SATZANW EPOS block selection 32 I32 (bit-serial)
MDI_TARPOS MDI position 34 I32 p2642
MDI_VELOCITY MDI velocity 35 I32 p2643
MDI_ACC MDI acceleration 36 I16 p2644
MDI_DEC MDI delay 37 I16 p2645
MDI_MOD MDI mode specification 38 U16 (bit-serial)
1) Data type according to PROFIdrive profile V4:
I16 = Integer16, I32 = Integer32, U16 = Unsigned16, U32 = Unsigned32
2) Bit-serial interconnection: refer to the following pages